 |
 |
| 40W Triple Output |
 |
 APT-40A |
 |
 APT-40A |
 |
 APT-40C |
 |
 |
 |
| FEATURES |
|
Low-cost, high reliability |
|
Built in EMI filter, low ripple noise |
|
Compact size, light weight |
|
Short circuit/over load protection |
|
 |
| Type No | Output | Tol. | R & N | Effi. | | CKT-40A | 5V, 0.6-5A | ±2% | 100mV | 72% | | 12V, 0.2-3A | ±6% | 120mV | | -5V, 0.1-1A | ±8% | 100mV | | CKT-40B | 5V, 0.6-5A | ±2% | 100mV | 72% | | 12V, 0.2-3A | ±6% | 120mV | | -12V, 0.1-1A | ±8% | 120mV | | CKT-40C | 5V, 0.6-5A | ±2% | 100mV | 72% | | 15V, 0.2-2A | ±6% | 120mV | | -15V, 0.1-1A | ±6% | 120mV | | Input voltage | 85~264VAC full range | | Input frequency | 47~63Hz | | Inrush current | Cold start, 20A/115V, 40A/230V | | Output voltage | Refer to above (CH1: +10%, -5% ADJ.) | | Overload protection | 105% ~ 150%/115VAC ouptut pulsing mode | | Over voltage protection | CH1: 115% ~ 135% of output voltage | | Setup, rise, hold up time | 1.6s, 50ms, 16ms/115VAC; 800ms, 50ms, 60ms/230VAC | | Withstand voltage | I/P-O/P: 3KV, 1/P-FG: 1.5KV, 1 min | | Working temp | 0-50°C@100%, -10°C@80%, 60°C@60% | | Safety Standard | Design refer to UL 1950, TUV EN60950, CSA950 | | EMC Standard | Design refer to EN55022 class B, EN61000-4-2,3,4,5, EN61000-3-2,3 | | Connection | 7P/8.25mm pitch terminal block |
|
 |
|
|