| 120W Quad Ouput |   | |   APQ-120B |  |   APQ-120C |  |  |  |   APQ-120D |  |  |  
|  |  
| FEATURES |  
|  | High efficiency, low working temp. |  |  | Built in EMI filter, low ripple noise |  |  | Compact size, light weight |  |  | 100% full load burn-in test |  |  | Short circuit/over load protection |  |  | Over voltage protection |  |  | International AC input selected |  |  
|  |  | Type No | Output | Tol. | R & N | Effi. |  | CKQ-120B | 5V, 2-12A | ±2% | 80mV | 77% |  | 12V, 0.5-5A | ±6% | 120mV |  | -5V, 0.2-1A | ±6% | 80mV |  | -12V, 0.2-1A | ±6% | 120mV |  | CKQ-120C | 5V, 2-12A | ±2% | 80mV | 76% |  | 15V, 0.5-5A | +10, -5% | 150mV |  | -5V, 0.2-1A | ±6% | 80mV |  | -15V, 0.2-1A | +10, -5% | 150mV |  | CKQ-120D | 5V, 2-12A | ±2% | 80mV | 80% |  | 12V, 0.2-5A | ±6% | 120mV |  | 24V, 0.2-2A | ±6% | 180mV |  | -12V, 0.2-1A | ±6% | 120mV |  | Input voltage | 90~132VAC/180~264VAC selected by SW |  | Input frequency | 47~63Hz |  | Inrush current | Cold start, 30A |  | Output voltage | Refer to above (CH1: +10%, -5% ADJ.) |  | Over voltage protection | CH1: 115% ~ 135% of output voltage |  | Overload protection | 105% ~ 135% output shutdown |  | Setup, rise, hold up time | 200ms, 50ms, 20ms |  | Withstand voltage | I/P-O/P: 3KV, 1/P-FG: 1.5KV, 1 min. |  | Working temp | 0-50°C@100%, -10°C@80%, 60°C@60% |  | Safety Standard | Design refer to UL 1915, TUV EN60950 requirement |  | EMC Standard | Design refer to EN550022 class B, EN61000-4-2,3,4,5, EN60555-2,3 |  | Connection | 8P/9.5mm pitch terminal block | 
 |  |  |  |  |